定常glow He plasmaに対する探針の特性 Ⅱ
URI | http://harp.lib.hiroshima-u.ac.jp/it-hiroshima/metadata/4263 | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ファイル |
kenkyukiyo0801057.pdf
( 165.0 KB )
公開日
:2009-08-17
|
||||||||||||||||||||||||
タイトル |
定常glow He plasmaに対する探針の特性 Ⅱ
|
||||||||||||||||||||||||
別タイトル |
An Electrostatic Probe Technique for the Measurement of Low Glow Plasma II
|
||||||||||||||||||||||||
著者 |
|
||||||||||||||||||||||||
抄録 |
The previous letter had described on the characteristics of the Langmuir-probe, doubleprobe and coaxial-probe on the stable glow plasma which was confined by weak Z-magnetic field. And as the result of the characteristic curves, the plasma electron temperature had been obtained nearly 105(○K). This letter describes on the characteristics of coaxial-probe and the measurement of the glow plasma. In this time, anode voltage is made twice for the measurement. In consequence, plasma electron temperature and density is 2×104~4 x104(○K) and 6x 1010~9 X 1010 (electron/cm3) respectively. |
||||||||||||||||||||||||
掲載雑誌名 |
広島工業大学研究紀要
|
||||||||||||||||||||||||
巻 |
8
|
||||||||||||||||||||||||
号 |
1
|
||||||||||||||||||||||||
開始ページ |
57
|
||||||||||||||||||||||||
終了ページ |
61
|
||||||||||||||||||||||||
出版年月日 |
1973
|
||||||||||||||||||||||||
出版者 |
広島工業大学
|
||||||||||||||||||||||||
ISSN |
03851672
|
||||||||||||||||||||||||
NCID |
AN0021271X
|
||||||||||||||||||||||||
本文言語 |
日本語
|
||||||||||||||||||||||||
資料タイプ |
紀要論文
|
||||||||||||||||||||||||
著者版フラグ |
出版社版
|
||||||||||||||||||||||||
旧URI | |||||||||||||||||||||||||
区分 |
it-hiroshima
|